Product Details
Place of Origin: China
Brand Name: CNP NM FIRE
Certification: ISO/CCCF/UL
Payment & Shipping Terms
Minimum Order Quantity: 1set
Price: Negotiation
Packaging Details: Export Package
Delivery Time: 35-40 Working Days
Payment Terms: L/C, T/T
Color: |
Red |
Casing: |
Ductile Cast Iron |
Impeller: |
Bronze |
Bearing: |
SKF |
Flow: |
1000usgpm And Others |
Use: |
Firefighting |
Color: |
Red |
Casing: |
Ductile Cast Iron |
Impeller: |
Bronze |
Bearing: |
SKF |
Flow: |
1000usgpm And Others |
Use: |
Firefighting |
NFPA20 Standard Mutil-stage Vertial Turbine Fire Pump Capacities Up To 10,000 GPM For Firefighting Use
Standards
NFPA20, UL, EN12845,CCCF
Performance Ranges
UL : Q: 250-5000GPM H:80-300PSI
FM: Q: 250-5000GPM H:80-300PSI
CCCF: Q:15-300L/S H:0.60-2.0Mpa
NFPA20: Q: 250-5000GPM H:80-300PSI
How It Works:
The vertical turbine pump is normally driven by an AC electric induction motor or a diesel engine via a right angle drive. The end of the pump consists of a rotating impeller that is joined to a shaft and guides the well water into a diffuser casing known as a bowl.
Pumps with multi-stage arrangements use several impellers on a single shaft to generate higher pressure that would be required for pumping water from deeper wells or where higher pressure (head) is required at ground level.
A vertical turbine pump works when water comes through the pump from the bottom through a bell-shaped device known as a suction bell. The water then moves into the first stage impeller, which increases the velocity of the water. The water then moves into the diffuser casing directly above the impeller, where the high velocity energy is transformed into high pressure. The diffuser casing also guides the fluid into the next impeller located directly above the diffuser casing. The process goes on through all the stages in the pump.
After leaving the diffuser casing, the water passes in a vertical column pipe and rises toward the surface. The rotating shaft within the column is propped at 3 to 5 foot intervals using sleeve bushings that are set within the column and they are lubricated by the water as it moves past them. The pump also has a discharge head at the surface which allows the flow to change direction toward the discharge pipe. An upright standing high thrust A.C. motor is fitted above the pump’s discharge head.
①The late-mover advantage of products, we R&D better fire products than other Suppliers;
②Have the most complete and all series of fire pump models;
③Have listed diesel engines with self-owned brand--- NM FIRE;
④Understand the technology of fire- fighting products and fire- fighting system better than other competitors and have better services;
⑤Shorter delivery time.
NM FIRE Vertical Shaft Turbine UL FIRE PUMP | ||||
NO. | Pump Model / Outlet Size / Min Submergence | Flow | Head | |
(usgpm) | (psi) | (m) | ||
1 | 100VTP40~6 Outlet Size 4" Min Submergence |
100 | 40~270 | 28~190 |
150 | 40~263 | 28-185 | ||
200 | 40~259 | 28~182 | ||
250 | 40~253 | 28~178 | ||
2 | 150VTP200~17 Outlet Size 6" Min Submergence |
500 | 40~213 | 28~150 |
750 | 40~182 | 32~24 | ||
500 | 40~230 | 28~162 | ||
750 | 45~188 | 44~32 | ||
3 | 200VTP250~22 Outlet Size 8" Min Submergence |
750 | 55~288 | 50.8~40 |
1000 | 50~267 | 36~188 | ||
750 | 40~263 | 28~185 | ||
1000 | 40~249 | 28~175 | ||
4 | 250VTP400~28 Outlet Size 10" Min Submergence 151cm |
1250 | 41~305 | 28~214 |
1500 | 40~292 | 28~205 | ||
1500 | 58~285 | 40~200 | ||
2000 | 63~251 | 44~176 | ||
5 | 250VTP550~26 Outlet Size 10" Min Submergence 171cm |
2000 | 40~194 | 28~185 |
2000 | 57~266 | 40~187 | ||
2500 | 61~245 | 43~172 | ||
6 | 300VTP860~43 Outlet Size 12" Min Submergence 180cm |
2500 | 50~245 | 35~172 |
3000 | 53~235 | 37~165 | ||
7 | 350VTP860~43 Outlet Size 12" Min Submergence 180cm |
2500 | 74~236 | 52~166 |
3000 | 69~230 | 48.5~162 | ||
3500 | 73~222 | 51~156 | ||
4000 | 104~207 | 73~145 | ||
8 | 350VTP1250~36 Outlet Size 14" Min Submergence 250cm |
3500 | 48~250 | 34~176 |
4000 | 46~244 | 33~172 | ||
9 | 400VTP1250~36 Outlet Size 16" Min Submergence 250cm |
4000 | 61~270 | 43~190 |
4500 | 60~264 | 42~186 | ||
5000 | 253 | 178 |
In addition to the above models, there are many model UL/FM testing in process.
Looking forward to your enquiry.
Q1.Do you have the UL-LISTED Fire Pump Sets?
Yes, We have the UL/FM and NFPA standard Fire Pump Sets.
Q2.I need your motor drive End-suction/Split-casing fire pump, what information shold I sent to you ?
Sir/Madam,you can privide the Capacity, Heed, Voltage and Frequncy,we will make the quotation for you,If you need Jockey Pump or other accessories, please tell us together.
Q3.If I need your Diesel Engine Drive End-suction/Split-casing fire pump, what information shold I sent to you ?
You can sent the Capacity Heed, Temperature and Altitude (temperature and altitude will affect the performance of diesel engines).If you need Jockey Pump or other accessories, please tell us Voltage and Frequncy or accessories together.
Q4.I need the UL/FM Vertical Tubine Fire Pump Set ,please sent me the price.
For the motor Diver Vertical Tubine Fire Pump Set: you shoul give us the Capacity, Heed, Voltage Frequncy and the tank deep.
For the Diesel Engine Drive Vertical Tubine Fire Pump Set:you should give us the Capacity, Heed and the tank deep.
If you need Jockey Pump or other accessories,please tell us together.
Service:
1. To supply high-quality products with reasonable prices in food additive industry. |
2. To follow orders and arrange shipping in time, providing complete documents |
for Customs clearance according to different export policies in different countries. |